Shaded 1957 ranch, microinverter retrofit

Residential · Five Points, Raleigh

Shaded 1957 ranch, microinverter retrofit

Two willow oaks, a 4:12 roof and an owner who had been told solar would not work here.

  • Array6.6 kW DC
  • Modules15 x 440 W
  • InvertersMicroinverter per module
  • Planes used2 (south and west)

Record

Full specification

Array
6.6 kW DC
Modules
15 x 440 W
Inverters
Microinverter per module
Planes used
2 (south and west)
Modelled year one
8,200 kWh
Measured year one
8,410 kWh

The problem

Two mature willow oaks on the south property line put the main roof plane at a total solar resource fraction of 71 percent between November and February. A previous contractor had quoted a string system across both planes, which would have let the shaded modules pull down the unshaded ones every winter afternoon.

The service panel was an original 100 A board with no spare spaces and a bus rating that ruled out a back fed breaker of the size required.

What we did

Microinverter per module so each panel produces independently. A shaded module at 40 percent output no longer costs its neighbours anything.

Split the array across the south and west planes rather than forcing everything onto the shaded south face, which raised the late afternoon yield in summer.

Replaced the 100 A panel with a 200 A service and moved the meter base at the same time, which was going to be needed within a decade regardless.

What happened

Measured first year production came in at 8,410 kWh against a modelled 8,200 kWh, about 2.6 percent above model.

Per module telemetry showed exactly the winter afternoon dip predicted by the shade study, which gave the owner confidence that the model was honest rather than optimistic.

The new service left headroom for the Level 2 charger the household added the following spring.

What we took from it

On heavily shaded lots the microinverter premium is not a luxury. A string design here would have cost the owner several hundred kilowatt hours every winter and would have been impossible to diagnose from a single inverter reading.

From the owner

Two companies told us the oaks made it pointless. Voltaic showed us the shade numbers month by month and built for them instead of around them.
Priya RaghunathanHomeowner, Five Points
Contemporary home with solar panels and lush garden by the river.

Start with the numbers, not a sales visit

Send twelve months of kWh and a roof photo. You get a sized system, a production model and a payback figure before anyone comes out.

No pressure appointment. The site check is free and the design is yours to keep.

Cookie preferences

Choose which cookies you allow. You can change this at any time from the link in the footer.